Exterior wall, U=0,29 W/m²K

Edit calculation
Thermal protectionMoisture proofingHeat protection
U-value: 0,29 W/m²K
Surface temperature.:
inside (min/medium): 17.6 / 17.6 °C
outside (min/medium): -14.6 / -14.6 °C
sd-value: 2,67 m
No condensate
Drying reserve: 1176 g/m²
Temp.Amplitudendämpfung: 526,3
phase shift: 18,5 h
heat storage capacity: 684 kJ/m²K
heat storage capacity: 581 kJ/m²K

Impact of each layer and comparison to reference values

For the following figure, the thermal resistances of the individual layers were converted in millimeters insulation. The scale refers to an insulation of thermal conductivity 0,045 W/mK corresponding to 'Mineraldämmplatte' in this component. The millimeter scale also shows, how much additional insulation would be necessary to achieve various standards.


Something went wrong... You should see an image instead of this text. Please let me know with which browser you experienced this problem.

Moisture proofing

This component is free of condensate under the given climate conditions.

Mould protection

The temperature of the inside surface is 17,6 °C leading to a relative humidity on the surface of 58 %.

Mould formation is not expected under these conditions.

Note: This is only an extract of the component analysis. Important information on possible defects may be missing. You will get the complete analysis when you open the component in the editor.

Nutzen Sie bereits den für Sie idealen Zugang zu u-wert.net?

ohne Konto
(kostenlos)
mit Konto
(kostenlos)
Plus-Option*
Infos & Kosten
PDF-Option*
Infos & Kosten
U-Wert
Feuchteschutz
Hitzeschutz
Wärmeverluste
Amortisierung
Gewerbliche Nutzung
Werbefreies Rechnerlayout
Anpassbares PDF-Dokument
Baustofffarbe frei wählbar
Baustoffe aus DIN 4108-4 & DIN 10456
U-Wert nach DIN 6946
Speicherplätze für Berechnungen 15100250
Eigene Baustoffe 10100100
  Anmelden Jetzt testen Jetzt testen

*U-Wert, Feuchteschutz, Hitzeschutz, Amortisierung und Wärmeverluste sind Teil des kostenlosen Basis-Kontos.

All data and calculations are for information only and must be checked prior to use by a competent person. You agree to our terms and conditions.
Commercial use only with Plus-Option, PDF-Option or Profi-Option.

We use cookies to personalise content, analyse access to our website and process your calculations. Privacy policy

Accept Leave page